DXEVAL system variable


Function Description:

The DXEVAL system variable is used to control when data extraction tables are compared against the data source. It may display update notification when the data is not current.

Type : Integer
Saved in : Drawing
Initial value : 12
Range : 0 ~ 511

System Variable Value:

0 : no notification
1 : open
2 : save
4 : print
8 : publish
16 : eTransmit/ Archive
32 : automatically update when saving
64 : automatically update when printing
128 : automatically update when printing
256 : automatically update when eTransmiting/ Archiving



Article ID: 1528
Created: July 14, 2021
Last Updated: July 14, 2021
Author: GstarCAD MY /KW

Online URL: https://www.gstarcad.com.my/knowledge/article/dxeval-system-variable-1528.html